Single Or Dual Extinguishing Outputs
Configured to provide a single or secondary extinguishant releasing output. Supports common or main/reserve cylinder setups, improving system resilience and reducing downtime after activation.
A development of its proven Sigma A-XT range which has been installed globally in its thousands, the Sigma ZXT UL provides controls and indications for a single-area extinguishing release system, enabling targeted extinguishing that limits damage and reduces cost.
Three conventional detection zones provide the alarm ‘trigger’ required to activate the release of extinguishant, and the system can be configured to release the extinguishant on an alarm from any single zone or combination of multiple zones.

Configured to provide a single or secondary extinguishant releasing output. Supports common or main/reserve cylinder setups, improving system resilience and reducing downtime after activation.

Up to 4 individual user access protected with unique six-digit passcode or by the optional enable control key switch. All access is recorded in the event log.

LED status indicators provide notification of the detection and extinguishing system status. The LCD displays system status including a visual countdown display for extinguishing release.

Record and download all events occuring on the system from Alarms, Troubles, Disablements etc. Storing upto 1000 events, it provides historical data for event diagnostics and investigations following an extinguishing release.

Supports up to 7 Status Indicator panels and 7 ZXT UL Ancillary boards via RS485 communication, enabling flexible and scalable expansion for larger protected areas.

Three Notification Appliance Circuits (NAC) can be configured with three patterns - Steady, March, Temporal 3 to support synchronisation for Strobe and Horn/Strobe devices.
We require some details in order for you to download this document.
Click to download the documentation
Sigma ZXT extinguishant releasing control panel UL/FM approved datasheet
Sigma ZXT UL
Sigma ZXT UL
7165-2298:0509
"*" indicates required fields
Sigma ZSi UL status units are a UL approved accessory to the Sigma ZXT UL extinguishant release panel. The units provide remote system status indications and minimal controls at additional points of access and egress for the protected area.
The Sigma ZXT Ancillary Board is compatible with all Sigma ZXT control panels. The board provides volt-free, normally-open contacts, enabling control of sub-systems and plant remotely from the main panel over a two-wire data bus.
The Sigma A-XT Abort Switch connects to the Abort terminals of the Sigma A-XT releasing panel. Any number of Sigma A-Si Abort Switches may be connected to the circuit.
Key removable in either position
Both sides of solenoid circuit are mechanically disabled during activation
Disablement illuminated at panel when active