Kentec Electronics Ltd /
  • Products
    • Addressable Fire Detection
      • Taktis EN
      • Syncro AS
      • Syncro View
      • Syncro AS Lite
      • Graphics
      • Vizulinx
      • Addressable Matrix
      • Addressable Ident
      • IO Board Enclosure
      • Addressable Sounder
        Controller Unit
      • Syncro Network Card
      • Dual Loop Module
      • Taktis Media Gateway Card
      • Taktis 4-Way Sounder Card
      • Expansion Cards 4 Way Conventional Detection Zone Module
      • Expansion Cards 6 Way Sounder Extender Board
      • Taktis 8-Way Relay Card
      • Taktis 8 Zone Conventional Card
      • Expansion Cards 8 Way Extender Board
      • Taktis 16 Channel I/O Card
      • Expansion Cards 16 Channel I/O
    • Conventional Fire Detection
      • Sigma CP
      • Sigma CP-A
      • Sigma CP-R
      • Vizulinx
      • Sounder Controller Unit
      • Sigma CP Sounder Controller Unit
      • Line Continuity Monitoring Unit
      • Sigma CP Ancillary PCB
    • Extinguishant Control
      • Sigma ZXT
      • Sigma XT+
      • Syncro XT+
      • Sigma XT
      • Sigma SI
      • Vizulinx
      • Addressable Matrix
      • Addressable Ident
      • Sigma XT Extinguishant
        Hold Off Units
      • Sigma XT Main/Reserve Duty Extinguishant Keyswitch Unit
      • Sigma XT Extinguishant
        Abort Button
      • Sigma XT Ancillary Board
      • Expansion Cards 6 Way Sounder Extender Board
      • Expansion Cards 8 Way Extender Board
      • Expansion Cards 16 Channel I/O
      • Apollo Test Set
    • Wired Fire Detection
      • K-System EN
        Wired Fire Detection
      • K-System UL
        Wired Fire Detection
    • Wireless Fire Detection
      • K-Mesh
        Wireless Fire Detection
    • Wireless Lockdown Notification System
    • Gas Detection
      • K-Detect-iON
        Calibration-Free Sensing
    • Emergency Voice Communications Systems
      • Safe-Point
      • Public Address and Voice Evacuation System (PA/VA)
    • Graphics
    • UL/ FM Approved
      • Taktis® UL
      • Elite RS
      • Sigma ZXT UL
      • Graphics
      • eView
      • XT+ Releasing Unit
      • Sigma A-CP
      • Sigma A-CP Annunciator
      • K-System UL
        Wired Fire Detection
      • Sigma A-XT
      • eMatrix
      • Sigma A-SI
      • Sigma ZSi UL
      • Taktis UL Vision Network Repeater
      • Taktis UL Media Gateway Module
      • Taktis UL Network Module
      • Sigma A-XT Disablement Switch
      • Sigma A-XT Extinguishant Abort Switch
      • Sigma A-XT Ancillary PCB
      • Sigma ZXT UL Ancillary Board
      • UL 10.25 Amp Power Supply
      • eNet
      • Elite I/O
    • Custom Build
    • Marine
    • Intelligent Networking and Communications
    • Miscellaneous
      • Warning Signs
      • Tamper Resistant Vision Window
      • Docbox
      • Printer Enclosure
      • Relay Board and Unit
      • Plant Isolate/Audio Visual
      • Remote Indicator Unit
    • Power Supplies & Battery Chargers
      • PSU – 10.25A
      • PSU – 2.5A & 5.25A
  • Resources
    • Software
    • Product Bulletins
    • Product Resources
    • Engineer’s Tools
  • Training
  • Kentec Partners Network
    • Kentec Installation Partner
    • Kentec Authorised Distributor
    • Kentec Authorised Distributor Plus
    • Find Kentec Partners
    • Become a Partner
  • About Kentec
    • About Kentec
    • News
    • Events
    • Technology Partners
  • Projects & Applications
    • Case Studies
    • Battery Energy Storage Solution (BESS)
    • Waking Watch
    • Martyn’s Law
    • Heritage
    • High Rise
  • Partner Portal
Kentec Electronics Ltd
  • Home
  • Products
  • News
  • LE2 Software
  • Partner Portal
  • Consultant Portal
  • Contact
MENU
  • PRODUCTS

    Addressable Control Panels

      EN

    • Taktis EN
    • Syncro AS

      UL

    • Taktis® UL
    • Elite RS

      Marine

    • Syncro ASM

    Conventional Control Panels

      EN

    • Sigma CP
    • Sigma CP-A

      UL

    • Sigma A-CP

    Extinguishant Control Panels

      EN

    • Sigma ZXT
    • Sigma XT
    • Sigma XT+
    • Syncro XT+

      UL

    • Sigma ZXT UL
    • Sigma A-XT
    • XT+ Releasing Unit

    Detection Systems

      EN

    • K-System EN
      (Addressable)
    • K-Mesh
      (Wireless)

      UL

    • K-System UL
      Wired Fire Detection

    Flammable Gas Detection

    • K-Detect-iON
      Calibration-Free Sensing

    Voice Systems

    • Safe-Point
    • Public Address and Voice Evacuation System (PA/VA)

    Custom Build

    Wireless Lockdown Notification System

    Intelligent Networking and Communications

      iNS

    • iNS Passive Optic Network Module
    • iNS RS485 Network Module
    • iNS Remote Interface Modules
    • iNS Transient Suppression Module

      Graphics

    • AMX Graphical Fire Alarm Management
    • Vizulinx

    PSUs & Warning Signs

    • Power Supplies and Battery Chargers
    • PSU – 2.5A & 5.25A
    • PSU – 10.25A
    • UL 10.25 Amp Power Supply
    • Warning Signs
  • RESOURCES

    Product Bulletins​

    Engineer's Tools

    Guides and Whitepapers

    Product Resources

  • TRAINING
  • PARTNERS NETWORK

    Find Kentec Partners

    Become a Partner

  • CASE STUDIES
  • APPLICATIONS

    Battery Energy Storage Solution (BESS)

    Waking Watch

    Martyn's Law

    Heritage

    High Rise

  • ABOUT

    About Kentec

    Events

    Technology Partners

    Memberships

Contact us

+44 (0) 1322 222121 sales@kentec.co.uk

News

BlogCategories

  • Articles
  • News
  • Product Launch

Kentec says it’s time to take another look at Taktis 17 Apr 2024

Kentec Electronics, the leading manufacturer of innovative life safety solutions, has introduced a range of new features to its cutting-edge Taktis analogue addressable fire alarm control panel. 

Packed with innovative new functionality to protect even the most complex buildings, Taktis is now the perfect solution for a wide range of applications including schools, hospitals, multi-site retail and critical national infrastructure, as well as commercial and industrial facilities.

The critical signal paths of a control panel are the lifeline of an entire fire detection system and issues with power supplies, communication modules and control circuits can have catastrophic consequences. To counter any disruption, the highest levels of redundancy have been incorporated into Taktis, which has multiple back-up microprocessors to eliminate the possibility of a single point of failure with the main microprocessor. Even if its touchscreen display fails, Taktis will continue to operate in reduced functionality mode, the loops will continue to operate and, if a detection device is activated, the panel and other panels on the network will be notified of the alarm condition.  

Taktis enables large installations to be fully standards compliant. EN 54-2 states that a system fault should not result in the loss of more than 512 detectors and while this is fine for installations with a single control panel with less than 512 connected devices, large installations can have many thousands of fire detection devices with multiple fire alarm control panels. Thanks to Kentec’s research and development, Taktis can now network up to 127 control panels and incorporates a fully redundant signal path using INS to mitigate risk, enhance fault tolerance and ensure that alarms are received across the network and importantly to the Alarm Receiving Centre. 

The latest version of Taktis also complies with the highest provisions of BS 7273-4, which applies to electrical control arrangements for actuation of mechanisms that unlock, release or open doors in the event of fire. Adhering to BS 7273-4 is increasingly important, as Annex A is now normative. 

There are three categories of actuation outlined in BS 7273-4, with Category A requiring failsafe operation under the most severe fault conditions. Through advanced cause and effects, the latest version of Taktis meets all the requirements of Category A. This means that door release mechanisms will continue to operate in the event of a fire, or during any event that leads to a fault on the critical signal path that could prevent a fire signal activating a release mechanism. 

The fire and rescue service in England attended 229,844 incidents in the year ending March 2022 that turned out to be false alarms. They can be particularly disruptive in hotels and similar accommodation-based businesses such as student accommodation and sheltered housing, so Taktis now boasts a ‘hotel mode’ feature.  

When Taktis is in this setting and a detection device activates, only the sounder in the room concerned will initially operate, while Taktis notifies where the event has taken place. A predetermined time period gives a competent person an opportunity to investigate and, if the activity causing the detector activation stops within that timeframe, the sounder will return to standby and Taktis will clear. In the case of a false alarm, this stops other alarms initiating a full-scale evacuation. 

 

Alongside industry leading levels of panel & network redundancy, BS 7273-4 Category A compliance and its ability to reduce false alarms, Kentec hasn’t forgotten the importance of ease of use. As such, the Taktis full colour seven-inch colour touchscreen has several additional customisable features particularly useful for smoke control operation and can be programmed in a wide variety of languages. This intuitive interface renders the system easy to use even for those with minimal or no training. 

‘The latest version of Taktis rubberstamps our commitment to providing the most advanced fire alarm control panel technology possible,’ commented Derrick Hall, director of sales and marketing at Kentec Electronics. ‘Taktis has become increasingly popular with members of the Kentec Installation Partner (KIP) Programme because its features make their lives easier and deliver significant benefits for end users. I would therefore encourage other fire detection and alarm installation professionals to take another look at Taktis.’ 

Take Another Look at Taktis

Get in touch. We're here to help.

Contact us
Kentec Electronics Ltd Kentec Electronics Ltd
25-26 Fawkes Avenue,
Questor, Dartford,
DA1 1JQ, UK
+44 (0) 1322 222121
[javascript protected email address]
Kentec Electronics Ltd
Explore
  • Home
  • Careers
  • Social Responsibility
Support
  • Product Branding
  • Engineer’s Tools
  • Company Certificates
  • Warranty and Repairs Policy
  • Coordinated Vulnerability Disclosure Policy
  • Hochiki Group Human Rights Policy
  • Terms and Conditions
Privacy Notice Terms of Use Cookies
    Follow us

©2026 Kentec Electronics Ltd. All Rights Reserved.

Success

Your form has been submitted successfully.

Registration Successful

Thank you for your interest. You have now been registered.

 

We will be in contact shortly with joining instructions.

 

Please be sure to check your junk/spam folder if you have not received your instructions within a few minutes.