Kentec Electronics Ltd /
  • Products
    • Addressable Fire Detection
      • Taktis EN
      • Syncro AS
      • Syncro View
      • Syncro AS Lite
      • Graphics
      • Vizulinx
      • Addressable Matrix
      • Addressable Ident
      • IO Board Enclosure
      • Addressable Sounder
        Controller Unit
      • Syncro Network Card
      • Dual Loop Module
      • Taktis Media Gateway Card
      • Taktis 4-Way Sounder Card
      • Expansion Cards 4 Way Conventional Detection Zone Module
      • Expansion Cards 6 Way Sounder Extender Board
      • Taktis 8-Way Relay Card
      • Taktis 8 Zone Conventional Card
      • Expansion Cards 8 Way Extender Board
      • Taktis 16 Channel I/O Card
      • Expansion Cards 16 Channel I/O
    • Conventional Fire Detection
      • Sigma CP
      • Sigma CP-A
      • Sigma CP-R
      • Vizulinx
      • Sounder Controller Unit
      • Sigma CP Sounder Controller Unit
      • Line Continuity Monitoring Unit
      • Sigma CP Ancillary PCB
    • Extinguishant Control
      • Sigma ZXT
      • Sigma XT+
      • Syncro XT+
      • Sigma XT
      • Sigma SI
      • Vizulinx
      • Addressable Matrix
      • Addressable Ident
      • Sigma XT Extinguishant
        Hold Off Units
      • Sigma XT Main/Reserve Duty Extinguishant Keyswitch Unit
      • Sigma XT Extinguishant
        Abort Button
      • Sigma XT Ancillary Board
      • Expansion Cards 6 Way Sounder Extender Board
      • Expansion Cards 8 Way Extender Board
      • Expansion Cards 16 Channel I/O
      • Apollo Test Set
    • Wired Fire Detection
      • K-System EN
        Wired Fire Detection
      • K-System UL
        Wired Fire Detection
    • Wireless Fire Detection
      • K-Mesh
        Wireless Fire Detection
    • Wireless Lockdown Notification System
    • Gas Detection
      • K-Detect-iON
        Calibration-Free Sensing
    • Emergency Voice Communications Systems
      • Safe-Point
      • Public Address and Voice Evacuation System (PA/VA)
    • Graphics
    • UL/ FM Approved
      • Taktis® UL
      • Elite RS
      • Sigma ZXT UL
      • Graphics
      • eView
      • XT+ Releasing Unit
      • Sigma A-CP
      • Sigma A-CP Annunciator
      • K-System UL
        Wired Fire Detection
      • Sigma A-XT
      • eMatrix
      • Sigma A-SI
      • Sigma ZSi UL
      • Taktis UL Vision Network Repeater
      • Taktis UL Media Gateway Module
      • Taktis UL Network Module
      • Sigma A-XT Disablement Switch
      • Sigma A-XT Extinguishant Abort Switch
      • Sigma A-XT Ancillary PCB
      • Sigma ZXT UL Ancillary Board
      • UL 10.25 Amp Power Supply
      • eNet
      • Elite I/O
    • Custom Build
    • Marine
    • Intelligent Networking and Communications
    • Miscellaneous
      • Warning Signs
      • Tamper Resistant Vision Window
      • Docbox
      • Printer Enclosure
      • Relay Board and Unit
      • Plant Isolate/Audio Visual
      • Remote Indicator Unit
    • Power Supplies & Battery Chargers
      • PSU – 10.25A
      • PSU – 2.5A & 5.25A
  • Resources
    • Software
    • Product Bulletins
    • Product Resources
    • Engineer’s Tools
  • Training
  • Kentec Partners Network
    • Kentec Installation Partner
    • Kentec Authorised Distributor
    • Kentec Authorised Distributor Plus
    • Find Kentec Partners
    • Become a Partner
  • About Kentec
    • About Kentec
    • News
    • Events
    • Technology Partners
  • Projects & Applications
    • Case Studies
    • Battery Energy Storage Solution (BESS)
    • Waking Watch
    • Martyn’s Law
    • Heritage
    • High Rise
  • Partner Portal
Kentec Electronics Ltd
  • Home
  • Products
  • News
  • LE2 Software
  • Partner Portal
  • Consultant Portal
  • Contact
MENU
  • PRODUCTS

    Addressable Control Panels

      EN

    • Taktis EN
    • Syncro AS

      UL

    • Taktis® UL
    • Elite RS

      Marine

    • Syncro ASM

    Conventional Control Panels

      EN

    • Sigma CP
    • Sigma CP-A

      UL

    • Sigma A-CP

    Extinguishant Control Panels

      EN

    • Sigma ZXT
    • Sigma XT
    • Sigma XT+
    • Syncro XT+

      UL

    • Sigma ZXT UL
    • Sigma A-XT
    • XT+ Releasing Unit

    Detection Systems

      EN

    • K-System EN
      (Addressable)
    • K-Mesh
      (Wireless)

      UL

    • K-System UL
      Wired Fire Detection

    Flammable Gas Detection

    • K-Detect-iON
      Calibration-Free Sensing

    Voice Systems

    • Safe-Point
    • Public Address and Voice Evacuation System (PA/VA)

    Custom Build

    Wireless Lockdown Notification System

    Intelligent Networking and Communications

      iNS

    • iNS Passive Optic Network Module
    • iNS RS485 Network Module
    • iNS Remote Interface Modules
    • iNS Transient Suppression Module

      Graphics

    • AMX Graphical Fire Alarm Management
    • Vizulinx

    PSUs & Warning Signs

    • Power Supplies and Battery Chargers
    • PSU – 2.5A & 5.25A
    • PSU – 10.25A
    • UL 10.25 Amp Power Supply
    • Warning Signs
  • RESOURCES

    Product Bulletins​

    Engineer's Tools

    Guides and Whitepapers

    Product Resources

  • TRAINING
  • PARTNERS NETWORK

    Find Kentec Partners

    Become a Partner

  • CASE STUDIES
  • APPLICATIONS

    Battery Energy Storage Solution (BESS)

    Waking Watch

    Martyn's Law

    Heritage

    High Rise

  • ABOUT

    About Kentec

    Events

    Technology Partners

    Memberships

Contact us

+44 (0) 1322 222121 sales@kentec.co.uk

News

BlogCategories

  • Articles
  • News
  • Product Launch

Kentec announces its ‘one-stop shop’ K-System fire detection solution 10 Jan 2025

09 January 2025… Kentec Electronics, the leading manufacturer of innovative life safety solutions, has announced the K-System, wired addressable fire detection.  Drawing on Kentec’s panel expertise which features an open protocol, K-System compliments Kentec’s proven wireless range, K-Mesh, making Kentec a ‘one-stop’ solution for wired and wireless addressable fire detection in both EN and UL standards. 

 

The K-System was created in response to the global market and specifiers requiring a single-branded system, whilst continuing its ethos of ‘open protocol’ and supporting its community of technology partners.  Solely available through Kentec Installation Partners (KIPs) and those on the Kentec Authorised Distributors Plus (KAD+) Programme, the K-System is backed by Kentec’s reputation for high quality, excellent technical support and comprehensive product training. 

K-System includes a range of high-performance intelligent detection devices, Manual Call Points, sounders, VADs (Visual Alarm Devices), interface modules and an assortment of ancillaries. The range also includes a highly sophisticated CO multi-sensor with 24 EN approved modes of operation. This device uses the CO sensing element not just for early detection of smouldering fires but to monitor the threat to life from COHb (Carboxyhaemoglobin) toxicity.  The K-System range will include UL variant, featuring 268 7th Edition addressable and conventional devices which will be available from February. 

K-System devices are fully configurable through the control panels configuration software providing such features, as adjustable sensitivity settings, day/night operating parameters, sounder tones/volumes, and enhanced cause and effect programming allowing K-System to be designed and configured to meet the needs of the application. 

Each K-System detection device has a unique type of code which enables the fire alarm control panel to identify what type of device has activated, this means users can tell whether an alarm has been generated from a smoke or heat sensor, a combination sensor or a manual call point, and an appropriate response is therefore ensured. An Interrupt System guarantees rapid responses from any device, and the time lapse between operation of a call point and indication of fire on the system is typically less than 1.5 seconds. 

K-System devices are electronically addressed using a special programming tool, restricting this operation to trained engineers only. Up to 254 loop addresses are supported on K-System devices with addresses 1-127 allocated to detection devices, Manual Call Points, interfaces etc. and addresses 128-254 allocated to base sounder/sounder beacon devices. In addition, K-System interface modules support sub-addressing where each input and output provided on an interface module are automatically allocated a sub-address of the main loop address, this allows independent monitoring, control, cause and effect programming for inputs and outputs. Sounder beacon devices also use sub-addressing to enable individual control of the sounder element and beacon element of the device. 

K-System devices and Kentec’s fire alarm control panels provide a wide range of features and configuration options, to meet users’ requirements. 

Get in touch. We're here to help.

Contact us
Kentec Electronics Ltd Kentec Electronics Ltd
25-26 Fawkes Avenue,
Questor, Dartford,
DA1 1JQ, UK
+44 (0) 1322 222121
[javascript protected email address]
Kentec Electronics Ltd
Explore
  • Home
  • Careers
  • Social Responsibility
Support
  • Product Branding
  • Engineer’s Tools
  • Company Certificates
  • Warranty and Repairs Policy
  • Coordinated Vulnerability Disclosure Policy
  • Hochiki Group Human Rights Policy
  • Terms and Conditions
Privacy Notice Terms of Use Cookies
    Follow us

©2026 Kentec Electronics Ltd. All Rights Reserved.

Success

Your form has been submitted successfully.

Registration Successful

Thank you for your interest. You have now been registered.

 

We will be in contact shortly with joining instructions.

 

Please be sure to check your junk/spam folder if you have not received your instructions within a few minutes.