Life Safety

System Specialists

  • Analogue Fire Detection
    Syncro ASSyncro AS ListecSyncroSyncro ViewSyncro MatrixSyncro IdentSyncro ModulesMulti Input/ Output UnitsSyncro I/O Boards & EnclosuresSyncro GUIDE
  • Conventional Fire Detection
    Sigma CPSigma CP-ASigma CP-RSigma CP AncillariesSigma MatrixK3000 SeriesLCMU
  • Extinguishant Control Panels
    Sigma XTSigma XT+Sigma XT+ CoincidenceSigma SiSigma XT Keyswitches & AncillariesSyncro XT+Syncro Si
  • Power Supplies & Battery Chargers
    Power Supplies & Battery Chargers2.5 & 5.25Amp PSUs10.25Amp PSU
  • Miscellaneous
    Sigma DocBoxTamper Resistant Vision WindowWarning signsRemote Isolate/ Audio VisualRemote Indicator UnitsWater DetectionSyncro As Printer Enclosure
  • UL/ FM Approved Panels
    Analogue Addressable Control PanelsEliteElite RSeVieweMatrixeNet16 Channel IO BoardConventional Control PanelsSigma A-CPSigma A-CP AnnunciatorExtinguishant Control PanelsSigma A-XTSigma A-Si Sigma A-XT Keyswitches & AncillariesPower Supplies10.25Amp PSU
  • Custom Engineered Solutions
  • Marine
    Syncro ASMSyncro View MarineSyncro ASM Voyage Data Recorder (VDR)

Sigma CP Ancillaries

Sigma CP

Ancillary PCB

  • The Sigma Ancillary Board is compatible with all Sigma CP and CP-R panels which have operating software version V2.0 or above.
  • The board provides common fire, common fault, coincidence and zonal fire, volt free contacts allowing control of sub-systems, graphical mimics and plant, remotely from the main panel over a two wire data bus.
  • Mains powered Ancillary boards require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.
  • A mixture of Ancillary boards, Sounder boards or Repeaters up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.

Documentation

  • Data Sheet

    DS39 Data Sheet (Ancillary PCB)
  • Manuals

    Man-1072 SB.02 Manual
    Man-1084 SB.04 Manual
    Man-1098 Main Manual
  • Other Useful Documents

    Sigma CP Schematic

Quick Links

Request a

Price List

"In The Loop"

Email Newsletter Registration

"In The Loop"

Email Archive

"Technical  Loop"

Email Archive

Request Product

Support CD

Download Kentec

Brochure

Events Kentec

are attending

Download

Product Manuals

Sounder Controller

Conventional Sounder

Controller Units

  • Conventional Sounder controllers enable additional, distributed power and control for sounder circuits in situations where there are insufficient circuits at the fire alarm control panel or where additional power is required to power heavily loaded sounder circuits.
  • The Sounder Controller Unit connects to conventional sounder circuits and any faults on its outputs are transmitted to the fire control panel via the incoming, triggering sounder circuit thus maintaining full fault monitoring.
  • All units contain a mains powered battery charger/power supply. There is space for up to 7 Ah batteries.
  • Indicators are provided for power healthy, power fault and sounder fault conditions and power fault conditions are signalled to the fire alarm control panel as a sounder fault.

Documentation

Sigma Sounder

Sigma CP Conventional Sounder Controller Units

  • The Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above.
  • The board provides 8 additional sounder outputs which can be configured as zoned, 2-stage or common alarm.
  • All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault.
  • A class change input is provided which, when activated by a volt free contact closing, will switch all sounder outputs on.
  • Mains powered units require only a two core data cable from the main control panel. 24V DC versions require an additional two cores from another 24V DC source which is suitably rated to supply the total sounder current. 230V versions have their own power supply which is rated to supply the full sounder load of 4 Amps.
  • Up to 7 Sounder boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. Sounder boards may be connected to the Sigma CP serial bus in addition to Sigma CP ancillary boards and Sigma CPR repeater panels.
  • The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres. Once Sounder boards have been recognised by the main panel, a fault will be announced at the main panel if any become disconnected.